Setup Menus; Resettable Total - Graco LDP5 Instructions Manual

Preset electronic metered dispense valves
Table of Contents

Advertisement

Operation

Setup Menus

AUTO
F
. 11
IG
1. If the display is blank
(Asleep), wake it by pressing
any button on the keypad.
2. Press and hold the Man-
ual/Reset and Auto/Reset
buttons simultaneously for
approximately six (6) seconds
to enter the Setup Menus.
NOTE: During the first four (4)
seconds, all segments display. Then for two (2)
seconds, the software version number displays.
3. There are five (5) Setup Menu screens available,
stored in a preset order. Press and hold the Auto /
Reset button to move through the menu screens.
a. First screen: Resettable Total Menu (F
page 12) - R-TOTAL (G) blinks in the lower right
corner on the screen.
12
PTS
QTS
GAL
LITERS
R-TOTAL
ti12053a
. 12,
IG
b. Second screen: Units of
Measure Menu (F
page 13) - the last set
Unit of Measurement
blinks in the lower right
corner on the screen.
c. Third screen: Calibration Menu (F
14) - CAL blinks on the screen.
d. Fourth screen: Auto Preset Amount Menu (F
15, page 14) - AUTO blinks and the currently
stored auto preset amount displays.
e. Fifth screen: Shut Off Default Amount Menu
(F
. 16, page 15) - the clock icon blinks and
IG
the stored shut off default amount displays.
The value displayed when leaving each menu is the
value that is stored.

Resettable Total

Resets the dispense total to zero or stores the dis-
played dispense total. The resettable total accumulates
until the next time it is manually reset.
AUTO
F
. 12
IG
1. If the Resettable Total screen is not already dis-
played, complete steps 1 - 3 in the Setup Menus,
page 12.
2. R-TOTAL blinks indicating that the Resettable Total
Menu screen is displayed. The currently stored total
and unit of measurement display.
. 13,
IG
. 14, page
IG
PTS
QTS
GAL
LITERS
R-TOTAL
ti12054a
312668ZAC
.
IG

Advertisement