Installation

Setup

The CSP valve is shipped ready to install in your sys-
tem. It has been factory-tested and should not require
any additional modification.
To install the CSP valve:
Select an appropriate mounting location for the CSP
valve and mounting bracket (if required).
When mounting the CSP valve:
the outlets must be in an easily accessible loca-
tion to aid with troubleshooting in case the sys-
tem is blocked.
the indicator pins must be visible.

Output Combination

The output volume of a CSP valve outlet can be
increased by installation of a doubling plug (17L651)
into an adjacent outlet. The doubling plug causes the
lubrication flow/output to be diverted to the next outlet
away from the inlet port. When one or more outlets are
plugged, the output is a multiple of the standard output.
For example:
One outlet provides 0.012 cu. in. (0.2 cc) of lubrication.
Installation of one (1) doubling plug increases the com-
bined lubrication total to 0.024 cu in. (0.4 cc) from the
outlet below the doubling plug.
Installation of two (2) doubling plugs in adjacent outlets
increases the combined lubrication total to 0.036 cu. in.
(0.6 cc) from the outlet below the second doubling plug.
NOTE: Do not close or plug Outlets 1 or 2.
3A3995L

Outlet Fitting Installation

Refer to F
. 1.
IG
F
. 1
IG
NOTE:
Always use Graco provided block outlet fittings
with clamping ring in block outlet. Any fittings with-
out a clamping ring will cause the lubrication sys-
tem to fail.
See CSP Divider Block Outlet Fittings, page 15, for
a complete list of available outlet fittings.