Ldp5 Meter Operation; Dispensing Fluid In Manual Mode - Graco LDP5 Instructions Manual

Preset electronic metered dispense valves
Table of Contents

Advertisement

Operation
3. Do one of the following:
a. To enter a new shut off
default amount, press
and hold the 10 button to
change the 10's digit,
the 1.0 button to change
the 1's digit,
and the 0.1 button to
change the first decimal
digit. Zero cannot be
entered.
NOTE: To reset the display to
0.00, press and hold the Manual /
Reset button.
b. Press and hold the Auto /
Reset button to lock in
the new shut off default
amount and return to the
unit to the Manual Dis-
pense Mode.
or
Press and hold the
Auto/Reset button to
return to the unit to the
Manual Dispense Mode.
16

LDP5 Meter Operation

Dispensing Fluid in Manual Mode

AUTO
F
. 17
IG
1. Press and hold the Man-
ual/Reset button.
If the display is blank
(Asleep), it wakes up and
displays the amount dis-
played before it fell
asleep.
If the display is awake, and the meter is in Man-
ual Dispense Mode, the display clears to 0.00.
If the display is awake, and the unit is in View-
ing Totals mode or Auto Dispense Mode, the
meter switches to the Manual Dispense Mode.
2. When the display is awake, it can dispense from
zero or from the displayed amount by doing one of
the following:
Press and hold the Man-
ual/Reset button again to
clear the display to 0.00 if
it is not already at 0.00.
Then go to step 3.
or
Go to step 3 to dispense from the displayed
amount.
PTS
QTS
GAL
LITERS
R-TOTAL
ti12053a
312668ZAC