Engine selections
Change the automatic fan control ON or OFF with this en-
gine setting. The fan configuration will change from auto-
matic to manual. At the automatic setting, both the speed
and direction (reverse) are controlled by the multi-function
display. The fan functions are determined by the hydraulic
oil temperature, engine coolant temperature, and charge
air. In the manual selection the fan speed is a set at the
maximum fan speed of 100%. The machine will default to
the automatic fan control setting.
Transmission selections
RevSpdDiff — Indicates speed differential between re-
verse and forward.
Shuttle — Adjusts ground drive ramps: smooth, moder-
ate, or aggressive.
Steer — Adjusts steering curves: smooth, moderate, or
aggressive.
Pedal — Adjusts transmission command (default).
Change from transmission pedal to deceleration pedal.
AutoPrkBrk — When the "AutoPrkBrk" function is set to
"ON", the unit is in neutral, and the UCM senses move-
ment from the drive motor speed sensors for 30 s, the
park brake will engage.
1. ON (default)
2. OFF
Max Speed — Sets speed in increments: 15, 13, 11, 9.
3 - CONTROLS AND INSTRUMENTS
3-49
13
RAIL12DOZ0213AA
14
RAIL12DOZ0649AA
15
RAIL14DOZ0583AA