SCR system technical faults, failures, and engine power loss levels
Visual display
Indicator
warning
light
DEF/AdBlue
Injection
Failed Torque
Limited"
DEF/AdBlue
Injection Failed
Power Limited"
DEF/AdBlue
Injection Failed
Power Limited"
DEF/AdBlue
Injection Failed
Power Limited"
Resetting the Selective Catalytic Reduction (SCR) system
For DEF/AdBlue® storage tank fluid level faults, failures that can cause engine power loss:
• The DEF/AdBlue® tank level must be raised above 15 % total volume.
• The key switch must be cycled to the Off position or throttle returned to low idle position.
For DEF/AdBlue® quality and SCR system technical faults, failures that can cause engine power loss:
• To fully reset the system, the component/failure causing the fault must be repaired or replaced.
• Switching off the engine will reset the system and the engine will restart at full power.
• If the same failure is re-detected within 40 h of engine operation, the last active engine power loss level will be
activated.
• If the same failure is detected three consecutive times within 40 h of engine operation, maximum engine power loss
will remain active after engine restart until the system is repaired.
• Please contact your authorized CASE CONSTRUCTION dealer for service.
Emergency re-start
NOTE: Emergency re-starts are only enabled after the engine has been commanded to low idle.
If full power loss is experienced, it may be impossible for the machine to move under its own power. Emergency
re-starts are available to provide the capability to move the machine.
• Allows 30 s of operation without power loss.
• After 30 s, the engine is automatically reduced to low idle speed.
• There is no limit to the number of emergency re-starts
3 - CONTROLS AND INSTRUMENTS
Indicator
Audible
light status
alarm
Active
Active
Active
Active
Active
Active
Active
Active
SCR fault/failure detected.
Up to 25 % torque reduction within 25 min of engine
running time. Contact your local authorized dealer for
repair.
SCR fault/failure detected 90 min after the initial warning
Up to 65 % torque reduction and 40 % engine speed
reduction within 40 min of engine running time. Contact
your local authorized dealer for repair.
SCR fault/failure detected 240 min after the initial warning.
Engine speed reduced to low idle within 30 min of engine
running time. Contact your local authorized dealer for
repair.
Emergency re-start is active.
No engine power loss. Engine will be reduced to low
idle after 30 s of continued operation. Contact your local
authorized dealer for repair.