Intermec MaxiScan 2200 Installation Manual page 92

Fixed-position scanner
Hide thumbs Also See for MaxiScan 2200:
Table of Contents

Advertisement

E Data transmission parameters
RS-232
An asterisk (*) indicates the predefined parameter settings for interface N° 100 (Standard RS-232 C).
time-out (hardware and software) - 1000 ms (*)
92
baud rate - 9600 (*)
data bits - 7 (*)
parity - even (*)
stop bits - 2 (*)
ENQ (Hex 05) - not used (*)
ACK (Hex 06) - not used (*)
NAK (Hex 15) - not used (*)
XON/XOFF software protocol - not active (*)
CTS/RTS hardware protocol - not active (*)
preamble - no preamble (*)
postamble - Carriage Return + Line Feed (*)
preamble + postamble - STX + ETX
code marks - not transmitted (*)
inter-character delay - none (*)
- 75 - 150 - 300 - 600 - 1200 - 2400 -
4800 - 19200 - 38400
- 8
- odd
- none
- 1
- ENQ (HEX 05)
- user-defined
- ACK (HEX 06)
- user-defined
- NAK (HEX 15)
- user-defined
- active
- active
- unlimited
- user-defined 1 to 2500 ms
- user-defined
- Carriage Return
- Line Feed
- user-defined
- no postamble
- transmitted
- default / user-defined
MaxiScan 2200 - Installation Guide