8 Set up the symbology parameters
Resetting symbology default settings
When you install and set up your MaxiScan 2200 for the first time, all the
symbology parameters are set to their factory default settings (see Appendix F).
The symbology default settings are global factory defaults—they are independent
of the different symbology activation codes.
If you want to reset all the default symbology settings, you can scan the Reset
Factory Defaults bar code provided in Appendix G, but you will then have to
completely reconfigure your MaxiScan 2200.
In most cases, it is easier to perform the following symbology reset procedure:
1. Scan the Disable All Symbologies bar code.
2. Select the activation codes for the symbologies you want to read.
3. Customize the symbology parameter settings if required.
The Disable All Symbologies code deactivates all the symbologies activated. If you want to deactivate
individual symbologies, use the Not Active codes for each symbology.
Disable All Symbologies does not reset the individual parameter settings for each symbology. When
you reactivate a symbology, you recover the parameter settings stored in memory for that symbology
when it was disabled.
42
Disable All Symbologies
MaxiScan 2200 - Installation Guide