9 Set up the operating parameters
Default values before standby:
initial standby: the laser beam is switched off after T = 15 minutes (900 seconds),
full standby: the rotating mirror motor is switched off after an additional period of T x 2 = 30
minutes and a total period of inactivity of T x 3 = 45 minutes.
Composing a different time before standby
1. Use your MaxiScan 2200 to read the Compose Time In Seconds Before Initial
Standby bar code.
2. Read each digit of the new time before initial standby using the number codes
provided at the end of this Installation Guide and scan the End Selection bar
code—provided with the number codes—to finish.
Example
To change the time before initial standby to 10 minutes (600 seconds):
1. Scan Compose Time In Seconds Before Initial Standby.
2. Scan 6, then 0, then 0.
3. Scan End Selection.
The MaxiScan 2200 will go into initial standby after 10 minutes and full
standby after a total of 30 minutes after the last read attempt.