Intermec MaxiScan 2200 Installation Manual page 45

Fixed-position scanner
Hide thumbs Also See for MaxiScan 2200:
Table of Contents

Advertisement

Codabar
Common parameter settings—Barcode length
Barcode length (number of characters) for Codabar = [start + barcode data + check digit if applicable +
stop]. The minimum length possible is 3 characters.
For maximum security and to optimize reading performance, we recommend that you use one
of the following parameters with the MaxiScan 2200:
Compose 1 or 2 or 3 Fixed Lengths (the best configuration if the codes in your application
have fixed lengths),
Compose Minimum Length.
Compose different lengths using the special number codes provided at the end of this Installation
Guide and scan End Selection once or twice as required:
minimum length:
Compose Minimum Length
<length>—End Selection
1 fixed length:
Compose 1 or 2 or 3 Fixed Lengths
<length>—End Selection—End Selection
2 fixed lengths:
Compose 1 or 2 or 3 Fixed Lengths
<first length>—End Selection
<second length>—End Selection—End Selection
3 fixed lengths:
Compose 1 or 2 or 3 Fixed Lengths
<first length>—End Selection
<second length>—End Selection
<third length>—End Selection—End Selection
MaxiScan 2200 - Installation Guide
Compose Minimum Length (default = 6)
Compose 1 or 2 or 3 Fixed Lengths
8 Set up the symbology parameters
45

Advertisement

Table of Contents
loading

Table of Contents