3 Transport/Storage/Disposal
Fig. 2: Securing the collecting tank against tipping over / rolling off
Valve pit
Fig. 3: Transporting the valve pit (example)
ü Transport equipment / lifting equipment suitable for the corresponding weight
(see data sheet) has been selected and is on hand.
1. Attach the valve pit to the lifting equipment as illustrated.
2. Transport the valve pit to the place of installation.
3. Carefully place down the valve pit at the place of installation. Protect it against
damage and secure it against rolling off.

3.3 Storage / preservation

CAUTION
Damage during storage due to frost, humidity, dirt, UV radiation or vermin
Corrosion / contamination of the collecting tank!
▷ Store the collecting tank in a dry, dark, frost-proof room not exposed to
sunlight where the atmospheric humidity is as constant as possible.
▷ Only remove caps / covers from the openings at the time of installation.
If commissioning is to take place some time after delivery, we recommend that the
following measures be taken:
Store the collecting tank in a dry, protected and frost-free room at constant
atmospheric humidity.