Mounting And Connecting Connectors; Mounting Tc To Target System - Renesas QB-78F1026 User Manual

In-circuit emulator
Table of Contents

Advertisement

QB-78F1026

2. 5 Mounting and Connecting Connectors

This section describes the methods of connecting the QB-78F1026 and target system.
Make connections with both the QB-78F1026 and target system powered OFF.
The following abbreviations are used in this section:
- TC: Target connector
- YQ: YQ connector
- EA: Exchange adapter
- MA: Mount adapter
- CA: Check pin adapter
- SA: Space adapter

2.5.1 Mounting TC to target system

(1)
Thinly apply a two-component epoxy adhesive (hardening time at least 30 minutes) to the ends of the four
projections on the base of the TC and adhere the TC to the user board (clean the surface of the target
system board using alcohol or the like). If alignment of target system pads to TC leads is difficult, align them
as in (2).
(2)
Align by inserting the guide pins for alignment for the TC (NQGUIDE) through the pin holes on the top of the
TC. Accessory holes are φ1.0 mm non-through holes in two or three places.
(For hole positions, see the particular TC drawing.)
(3) Solder after fitting the MA to the TC. This is to prevent troubles such as flux or solder splashing and adhering
to the TC contact pins when soldering.
- Soldering conditions
Caution Do not perform washing by flux immersion or vapor.
(4) Take away the guide pins.
R20UT0290JJ0100 Rev. 1.00
Sep 30, 2010
260°C × 10 seconds or less
Solder reflow
Manual soldering 350°C × 5 seconds or less (1 pin)
CHAPTER 2 SETUP PROCEDURE