Renesas QB-78F1026 User Manual page 29

In-circuit emulator
Table of Contents

Advertisement

QB-78F1026
<3> Connect the exchange adapter and emulation probe to the target connector.
<4> Connect the GND wire on the target system side of the emulation probe to the target system GND.
If a pin or screw is fastened to the target system GND, remove the transparent terminal cover on
the end of the GND wire and fasten the Y terminal of the GND wire to the target system (C in
Figure 2-6). If the GND on the target system is an exposed pad, likewise fasten the Y terminal to
the pad on the target system by soldering (recommended soldering iron temperature setting:
300°C).
<5> Since the length of the GND wire below the head (insulated part) is approximately 60 mm, there
must be a GND to which it can be connected to within the range of an approximately 60 mm radius
section of the target system for connecting the emulation probe, as shown in Figure 2-7.
R20UT0290JJ0100 Rev. 1.00
Sep 30, 2010
Figure 2-7. Where GND Wire Can Be Connected
L = 60
CHAPTER 2 SETUP PROCEDURE
27.5
30.75
Target system
Page 23 of 29