Power Connections
Figure 3
Wire Routing and Attachment for Cisco 2821 and Cisco 2851 Routers
1
0
Plastic covers
Approved Scenarios and Scenarios Not Approved for Dual DC Power Supply Configuration in Cisco
2800 Routers
You can connect a single DC power source to either the A input or the B input. If there are dual power
sources, connect one source to the A input and one source to the B input. Both sources must be the same
polarity (with respect to ground) and voltage (within 0.25 volts). Do not connect –DC grounded and +DC
grounded dual sources to Cisco 2811, Cisco 2821, and Cisco 2851 routers.
Dual sources with opposite-polarity grounding damage equipment.
Caution
Cable Connection Procedures for Cisco 2800 Series Routers
6
C O N S O
L E
A U X
2 4 - 6 0 V
- - - 1 2 A
-
A
+
+
B
-
Cable tie
From DC
power
source
OL-5787-02