Kärcher ABS WSO SB-Wash Manual page 24

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
Pump does not
Buffer tank for permeate is full
start
Level switch Buffer tank is full is defective
Start-up time of the control has not yet
been completed
Pressure switch for water scarcity is defec-
tive
Regeneration of the base exchanger is
running
No softened water is coming from the base
exchanger
Pump continu-
Finest filter or active carbon filter is dirty
ously goes on
Regeneration of the base exchanger is in-
and off
complete
Pump starts only
Too low mains water pressure
after several rins-
ing cycles
Finest filter or active carbon filter is dirty
Permeate output
Water inlet temperature is too low
is too low; buffer
tank of permeate
Operating pressure is too low
is often empty
There are calcium or mineral deposits on
the filter surface of the RO membrane.
Level switch Buffer tank is "full" is defec-
tive
There are bacteria or algae deposits on
the filter surface of the RO membrane.
There are stains
The mineral content of the softened water
on the car paint
is too high
during Top Care
RO membrane has ruptured; defective
(permeate has
sealing
not been ade-
quately deminer-
Mixing of permeate and softened water
alised)
Transport
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Storage
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
24
Wait until the permeate is consumed.
Check level switch.
Wait.
Check pressure switch; replace it, if required.
Wait for regeneration to end.
Check the base exchanger.
Check filter; replace the filter inlay, if required
Add salt, add water and wait for brine formation (ap-
prox. 2 hours); start regeneration, check the base ex-
changer, if required.
Check mains water supply; open the inlet valve fully,
if required.
Check filter; replace the filter inlay, if required
Measure the temperature of the softened water and
compare it with the technical data.
Reset the operating pressure.
Decalcify the membrane; replace it, if necessary
Check level switch.
Rinse the membrane thoroughly for a long time; re-
place it if necessary. In future remember: Water is of
potable quality; avoid long idling periods.
Check conductivity of softened water.
Replace washer or membrane. Check conductivity
Comparison of conductivity of the permeate from the
spray pipe and water from the buffer tank of perme-
ate.
10
-
EN
Operator
Customer
Service
Operator
Customer
Service
Operator
Operator/
Customer
Service
Operator
Operator/
Customer
Service
Operator
Customer
Service
Operator
Customer
Service
Customer
Service
Customer
Service
Customer
Service
Customer
Service
Customer
Service
Customer
Service

Advertisement