7.5.2
This setting sets an amount by which the X-coordinate is shifted to the left or right.
Max.
Min. value
value
+99.9
-99.9
Default value: 0.0mm
<Supplemental Explanations>
(1)
The X-coordinate fine adjustment setting is performed to finely shift the x-coordinate of graphic data to the
right or left.
X-coordinate is shifted in the minus direction and reaches its origin (0), it cannot be further shifted and stays
at the origin.)
(2)
This fine adjustment is disabled for self-test print (maintenance counter values, various parameter values,
and automatic self-test) and test print.
Support mode (o:valid、x:invalid)
TPCL, TPCL1,
LABEL
o

X-coordinate Fine Adjustment (X Adjust)

Step
Display
0.1
Decimal
Paper
Feed
Direction
This fine adjustment is performed within the effective print width range.
C Mode
ESC/POS
RECEIPT,RECEIPT1
x
x
Sign
Integer
digit
Exist
2
XYZ
+
-81-
Decimal
0-padding
place
1
None
Z Mode
S Mode
x
x
Unit of
measure
mm
(When the

Advertisement