Chapter 10. Updating Firmware
Updating Firmware using XMODEM
10-2
Before beginning this procedure,
•
you must have a level 2 password for updating any module within
ATLAS. Please consult the ATLAS administrator if you do not know the
password.
•
you must obtain the appropriate update file for the particular module
from ADTRAN Technical Support at (888) 4ADTRAN (423-8726).
•
you may want to review Update Firmware on page 6-12.
Instructions for Updating Firmware Using XMODEM
Step
Using a VT-100 terminal emulation communication software
1
package which contains XMODEM protocol support, log in to
ATLAS.
2
Select System Utility / Update Firmware (see Figure 10-1).
Move the cursor to Module Slot , and press
appropriate module slot to update.
To update multiple modules of the same type, select All
3
Modules of a Type from Module Slot . (Only upgradable
modules are displayed as choices for Module Type when
updating All Modules of a Type in the ATLAS.)
4
Select XMODEM for Transfer Method .
From Restart Schedule , select the time for the module to perform
5
a restart after completing the update process (see Restart
Schedule on page 6-13).
View Current Update Status to verify the progress of the current
6
firmware update or any errors encountered during the download
process (see Current Update Status on page 6-14).
Select Begin Firmware Update to start the update process. Enter
to confirm the transfer and to set up the module to receive the
Y
XMODEM upload.
7
When ATLAS is ready to receive the XMODEM upload, the
menu screen will clear and display
Upload...... <CTRL-X> to Cancel
please review the steps above for possible configuration errors.
ATLAS 800 User Manual
Action
Enter
. Select the
Awaiting XMODEM
. If this does not appear,
61200180L1-1