Updating Firmware Using Xmodem - ADTRAN ATLAS 800 User Manual

Hide thumbs Also See for ATLAS 800:
Table of Contents

Advertisement

Chapter 10. Updating Firmware

Updating Firmware using XMODEM

10-2
Before beginning this procedure,
you must have a level 2 password for updating any module within
ATLAS. Please consult the ATLAS administrator if you do not know the
password.
you must obtain the appropriate update file for the particular module
from ADTRAN Technical Support at (888) 4ADTRAN (423-8726).
you may want to review Update Firmware on page 6-12.
Instructions for Updating Firmware Using XMODEM
Step
Using a VT-100 terminal emulation communication software
1
package which contains XMODEM protocol support, log in to
ATLAS.
2
Select System Utility / Update Firmware (see Figure 10-1).
Move the cursor to Module Slot , and press
appropriate module slot to update.
To update multiple modules of the same type, select All
3
Modules of a Type from Module Slot . (Only upgradable
modules are displayed as choices for Module Type when
updating All Modules of a Type in the ATLAS.)
4
Select XMODEM for Transfer Method .
From Restart Schedule , select the time for the module to perform
5
a restart after completing the update process (see Restart
Schedule on page 6-13).
View Current Update Status to verify the progress of the current
6
firmware update or any errors encountered during the download
process (see Current Update Status on page 6-14).
Select Begin Firmware Update to start the update process. Enter
to confirm the transfer and to set up the module to receive the
Y
XMODEM upload.
7
When ATLAS is ready to receive the XMODEM upload, the
menu screen will clear and display
Upload...... <CTRL-X> to Cancel
please review the steps above for possible configuration errors.
ATLAS 800 User Manual
Action
Enter
. Select the
Awaiting XMODEM
. If this does not appear,
61200180L1-1