Chapter 5: Specifications; Gh1.5Kw Series Specifications - TDK-Lambda GH10-150 Product Safety & Installation Manual

Hide thumbs Also See for GH10-150:
Table of Contents

Advertisement

5.1 GH1.5kW Series Specifications

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0° to 50° Celsius.
OUTPUT RATING
1.Rated output voltage (*1)
2.Rated output current (*2)
3.Rated output power at 100Vac≤Vin≤265Vac, Ta≤50
INPUT CHARACTERISTICS
1.Input voltage/freq. (*3)
2.Maximum input current at 100% load (at 100Vac/200Vac)
3.Power Factor (Typ.)
4.Efficiency (Typ. at 100Vac/200Vac)(*17)
5.Inrush current (*5)
CONSTANT VOLTAGE MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*7)
3.Ripple and noise (p-p, 20MHz) (*8)
4.Ripple r.m.s. 5Hz~1MHz (*8)
5.Temperature coefficient
6.Temperature stability
7.Warm-up drift
8.Remote sense compensation/wire (*10)
9.Up-prog. response time (*11)
10.Down-prog. response time (*12)
11.Transient response time
12.Start-up delay
13.Hold-up time
CONSTANT CURRENT MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*9)
3.Ripple r.m.s. (*13)
4.Temperature coefficient
5.Temperature stability
6.Warm-up drift
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming
2.Iout voltage programming (*14)
3.Vout resistor programming
4.Iout resistor programming (*14)
5.Output voltage monitor
6.Output current monitor (*14)
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1.Power supply OK #1 signal
2.CV/CC signal
3.LOCAL/REMOTE Analog control
4.LOCAL/REMOTE Analog signal
5.ENABLE/DISABLE signal
6.INTERLOCK (ILC) control
7.Programmed signals
8.TRIGGER IN / TRIGGER OUT signals
9.DAISY_IN/SO control signal
10.DAISY_OUT/PS_OK #2 signal

CHAPTER 5: SPECIFICATIONS

10-150
V
10
A
150
W
1500
V
10
85~265Vac continuous, 47~63Hz, single phase.
---
18.5/9
A
---
0.99 @ 100Vac, 0.98 @ 200Vac, rated output power.
%
86/88
---
Less than 50A.
V
10
---
0.01% of rated output voltage.
---
0.01% of rated output voltage +2mV.
mV
50
mV
6
50PPM/
---
---
0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temperature.
---
Less than 0.01% of rated output voltage +2mV over 30 minutes following power on.
V
2
mS
20
Full load
20
mS
No load
300
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated
output current.
---
Output set point: 10~100%, Local sense.
Less than 1mS for models up to and including 100V. 2mS for models above 100V.
---
Less than 6Sec.
---
20mS Typical. Rated output power.
V
10
---
0.01% of rated output current +2mA.
---
0.02% of rated output current +5mA.
mA
≤250
10V~100V models: 100PPM/
---
150V~600V models: 70PPM/
0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
---
10V~100V models: Less than +/-0.25% of rated output current over 30 minutes following power on.
---
150V~600V models: Less than +/-0.15% of rated output current over 30 minutes following power on.
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
---
0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
---
0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
---
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
---
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
Power supply output monitor. Open collector. Output On: On. Output Off: Off.
---
Maximum Voltage: 30V. Maximum Sink Current: 10mA.
CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V.
---
Maximum Sink Current: 10mA.
Enable/Disable analog programming control by electrical signal or dry contact. Remote:
---
0~0.6V or short. Local: 2~30V or open.
Analog programming control monitor signal. Open collector. Remote: On. Local: Off.
---
Maximum Voltage: 30V. Maximum Sink Current: 10mA.
Enable/Disable PS output by electrical signal or dry contact.
---
0~0.6V or short, 2~30V or open. User selectable logic.
Enable/Disable PS output by electrical signal or dry contact.
---
Output ON: 0~0.6V or short. Output OFF: 2~30V or open.
Two open drain programmable signals. Maximum voltage 25V. Maximum sink current 100mA
---
(shunted by 27V zener).
Maximum low level input voltage = 0.8V. Minimum high level input voltage = 2.5V.
---
Maximum high level input = 5V positive edge trigger: tw = 10us minimum. Tr,Tf = 1us maximum.
Min delay between 2 pulses 1ms.
---
By electrical Voltage: 0~0.6V/2~30V or dry contact.
---
4~5V = OK, 0V (500Ω impedance) = Fail.
20-75
30-50
40-38
60-25
20
30
40
60
75
50
38
25
1500
1500
1520
1500
20
30
40
60
87/89
87/89
87/89
87/89
20
30
40
60
50
50
60
60
6
6
7
7
O
C from rated output voltage, following 30 minutes warm-up.
2
5
5
5
20
20
20
20
20
20
30
30
500
600
900
1200
20
30
40
60
≤130
≤100
≤60
≤50
O
C from rated output current, following 30 minutes warm-up.
O
C from rated output current, following 30 minutes warm-up.
61
80-19
100-15
150-10
300-5
80
100
150
300
19
15
10
5
1520
1500
1500
1500
80
100
150
300
87/89
88/90
88/90
88/90
80
100
150
300
75
130
75
180
8
30
20
45
5
5
5
5
20
20
30
30
50
50
60
70
1300
1700
2200
2700
80
100
150
300
≤30
≤40
≤10
≤8
600-2.6
600
2.6
1560
600
88/90
600
500
100
5
40
80
3000
600
≤5