This manual is a description of specifications, features and applications of LZS-A1000 power supplies.

RATINGS AND SPECIFICATIONS*

Maximum Ratings
Output Voltage Range
Output Current (Power) @ 60°C**
DC Output @ 12V
Output Current (Power) @ 70°C**
Operating Temperature
Start-up Temperature
Page. 3
401 Mile of Cars Way, Suite 325 • National City, CA 92154 • 1-800-LAMBDA-4
EN55022/EN55011
(0.15-30 MHz) Class B
EN55022/EN55011
30-1000 MHz Class B
EN61000-3-2
Class A Limits
EN61000-3-3
Complies
IEC61000-4-2
+/-8 kV Air
+/-6 kV Contact
IEC61000-4-3
10 V/m, 80 MHz-2.5GHz
80% AM @ 1kHZ
IEC61000-4-4
+/-2 kV AC Line, Criteria A
+/-1 kV I/O Line > 3m, Criteria A
IEC61000-4-5
+/-2 kV line to GND (CM), Criteria A
+/-1 kV line to line (DM), Criteria A
IEC61000-4-6
10 V/m RMS, 150 kHz-80 MHz
80% AM at 1kHz
3 A/m
IEC61000-4-11
5% of nom. line for .5 cycles - Criteria A
40% for 5 cycles - Criteria A
70% for 25 cycles - Criteria A
95% Dip for 5 seconds -
Unit should not latch
SEMI-F47
50% of nom. line for 200 msec
(110 VAC@1000W,
70% for 500 msec
220 VAC@1500W)
80% for 10 seconds
90% for 15 seconds
0% for 1 cycle or 20mS
6 kV/30 Ohm Criteria A
Units
V
A(W)
A(W)
°C
47-63Hz 100% rated load from -30°C to 60°C derate
linearly to 60% @ 70°C (4%/°C)
Over 63Hz to 440Hz 100% rated load from -30°C
to 55°C derate linearly to 60% @ 65°C (4%/°C)
°C
LZS-A1000-2 Power Supply
Table 1
LZS-A1000-2
10-15.75
84 (1008)
50.4 (605)
-40° to +70°
Table 2
Revision H : January 2022