Explanations On Specifications; Input Voltage Range - TDK-Lambda CN-A110 Series Instruction Manual

Table of Contents

Advertisement

■ Explanations on Specifications

1. Input Voltage Range

Input voltage range for CN-A110 Series is indicated below.
Input Voltage Range : 60 - 160VDC
Basically,ripple voltage (Vrpl) which results from rectification
and filtering of commercial AC line is included within the input
voltage as shown in Fig. 1-1. Ripple voltage must be limited within
the voltage described below.
Allowable Input Ripple Voltage : 10Vp-p
When this value is exceeded, the output ripple voltage
becomes large.
Note that sudden input voltage change may cause variation of
output voltage transitionally.
Also, input voltage waveform peak value must not exceed
above input voltage range.
Time
Fig.1-1 Input Ripple Voltage
Basic Connection
Fuse
+Vin
CNT
C1
PC/NC*
-Vin
Baseplate
Fig.1-2 Basic Connection
Input Fuse
This power module has no built-in fuse. Use external fuse to
acquire various Safety Standards and to improve safety.
Vrpl
below
10 V
+V
+S
C2
C3
TRM
CN-A110
-S
-V
* PC/NC terminal : Only CN200A
Also, use fast-blow type or nomal-blow type for every module.
Furthermore, fuse must be connected to the +Vin side if –Vin
side is used as ground, or fuse must be connected to –Vin side
if +Vin side is used as a ground.
Input Fuse Recommended Current Rating:
CN100A110 : DC400V and above , 5A
CN30,50A110 : DC400V and above , 4A
CN200A110 : DC400V and above , 10A
C1 :
To prevent the effect of input line inductance to the power
module, connect electrolytic capacitor between +Vin and –Vin
terminals.
Furthermore, use electrolytic capacitor with small ESR value.
Especially take note that during line turn off at low ambient
temperature, power module output will not normally shut down.
CN30,50,100A
Recommended Capacitor Value : 47μF and above
CN200A
Recommended Capacitor Value : 100μF and above
Notes
1.
temperature characteristics.
CN30,50,100A
CN200A
2.
connect capacitors as below to reduce equivalent
series resistance.
CN30,50,100A
+
CN200A
Load
-
(Nippon Chemi-con LXV Series or Nichicon PM Series or
equivalent)
3.
due to insertion of choke coil, operation of the power
module could become unstable. For this case, increase C1
value more than the value indicated above.
- 4 -
TDK-Lambda
CN-A110 Series
Instruction Manual
(Voltage Rating 200V and above)
(Voltage Rating 200V and above)
Use low impedance electrolytic capacitor with excellent
(Nippon Chemi-con KMQ, KXJ Series or equivalent)
(Nippon Chemi-con KXJ Series or equivalent)
When using at –20 ℃
Use two capacitors (100μF,100V) in series.
Use two series capacitors (120μF,100V) in two parallel.
When input line inductance becomes excessively high
ambient temperature,