Specifications; Output Rating (Duty Cycle Continuous Duty); Input Characteristics; Static Characteristics - TDK-Lambda GENESYS 15KW User Manual

Programmable dc power supplies
Hide thumbs Also See for GENESYS 15KW:
Table of Contents

Advertisement

2. SPECIFICATIONS

All specifications are subject to change without notice.
Contact factory for specific model availability.

2.1. Output Rating (Duty Cycle Continuous Duty).

2.1.1. Standard Models – 10kW
1. Rated Output voltage
2. Rated Output current
3. Rated Output power
2.1.2. Standard Models – 15kW
1. Rated Output voltage
2. Rated Output current
3. Rated Output power

2.2. Input Characteristics

1. Input voltage/freq. (range)
2. # of phases
3. Dropout voltage
4. Input current 180/342/432 VAC
5. Power Factor (typical)
6. Efficiency at Low Line, 100% load
7. Inrush current
8. Leakage current
9. Input Protection
10. Fuse
11. Phase Imbalance

2.3. Static Characteristics

1. Max. line regulation, CV
2. Max. line regulation, CC
3. Max load regulation, CV
4. Max load regulation, CC
5. Temperature Stability, CV
6. Temperature Stability, CC
7. Temperature Coefficient, CV
8. Temperature Coefficient, CC
9. Output noise p-p (20MHz), CV
10. Ripple r.m.s 5Hz∼1MHz, CV
11. Ripple r.m.s 5Hz∼1MHz, CC (10kW)
12. Ripple r.m.s 5Hz∼1MHz, CC (15kW)
13. Rem. sense compensation/wire
*Ripple and Noise at Vo(rated) and rated load at 25°C, nominal AC input, per EIJ RC9002A
V
7.5
10 12.5 20
25
A
1000 1000 800 500 400 333 250 200 167 125 100
kW
7.5 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 9.9 10.0 10.0 9.9 10.0 10.0 10.2
V
N/A N/A N/A N/A N/A
A
-
-
-
-
kW
-
-
-
-
V
7.5
10 12.5 20
25
---
208VAC (180-253), 400VAC (342-440), 480VAC (432-528), all 47-63Hz
---
3 Phase (Wye or Delta) 4 wire total (3 Phases and 1 Protective Earth ground)
V
175/338/425
A
10kW – 45/23/20, 15kW – 64/32/27; All at full rated Output power.
---
0.88 Passive (208VAC, 400VAC, 480VAC)
%
77 min for 7.5kW, 83 min for 10kW, 88 min for 15kW
A
Not to exceed full rated Input current
mA
3.5 (EN60950-1) max
---
Circuit breaker for 7.5V, 10V and 12.5V Outputs @ 10kW with 208VAC input.
---
Fuse for: 7.5V, 10V and 12.5V Outputs @ 10kW with 400VAC/480VAC input.
Fuse for: 20V ≤ Vout ≤ 600V @ 10kW/15kW with 208VAC/400VAC/480VAC input.
≤ 5% on Three Phase Input
%
V
7.5
10 12.5 20
25
---
0.1% of FS from lo(min) to
lo(max).
---
0.1% of FS from Vo(min) to
Vo(max).
---
0.1% of FS from lo(min) to
lo(max).
---
0.1% of FS from Vo(min) to
Vo(max).
---
+/- 0.05% of Vo(rated) over 8 hours after 30 minute warm up (constant Line, Load & Temperature).
---
+/- 0.05% of Io(rated) over 8 hours after 30 minute warm up (constant Line, Load & Temperature).
PPM/C
200 (0.02% of Vo(rated)/Degree C)
PPM/C
300 (0.03% of Io(rated)/Degree C)
mV
60
60
60
60
60
mV
20
20
20
20
20
mA
5300 4000 2560 1000 640 444 250 160
mA
-
-
-
-
-
V
1
1
1
1
1
21
83532002 Rev H
30
40
50
60
80
100 125 150 200 250 300 400 500 600
30
40
50
60
80
100 125 150 200 250 300 400 500 600
-
500 375 300 250 187.5 150 120 100
-
15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0
30
40
50
60
80
100 125 150 200 250 300 400 500 600
30
40
50
60
80
100 125 150 200 250 300 400 500 600
0.05% of FS from lo(min) to lo(max).
0.05% of FS from lo(min) to lo(max).
0.05% of FS lo(min) to lo(max).
0.075% of FS from Vo(min) to Vo(max).
60
60
75
75
100 100 125 150 175 200 200 300 350 350
20
20
20
20
25
25
67
50
40
350 200 150 100 100 100
1.5
2
3
3
4
5
80
66
50
40
33
25
20
75
60
50
37.5 30
25
25
35
35
60
60
60
32
26
20
16
13
10
50
50
20
20
20
10
10
5
5
5
5
5
5
17
25
60
8
7
10
5
5

Advertisement