14

P arallel-Port Interface

1 3 B
The coolMONSTER/PM incorporates an IBM XT/AT compatible parallel port. It supports uni-directional,
bi-directional, EPP and ECP operating modes.
14.1

C onnector

7 1 B
The parallel port is available through connector X11 (26 pins). To have the signals available on a
standard, parallel-interface connector DSUB-25, an adapter cable is required, which is available from
KONTRON (KAB-DSUB25-1, Part Number 96015-0000-00-0).
The following table shows the pin-out as well as necessary connections for a DSUB-25 adapter.
Header
Pin
1
3
1
2
5
7
9
11
13
15
17
19
21
23
25
26
2
25
4
6
8
26
10,12
14,16
18,20
22,24
Notes: (*)To protect the external power lines of peripheral devices, make sure that:
-- the wires have the right diameter to withstand the maximum available current
-- the enclosure of the peripheral device fulfils the fire-protecting requirements of IEC/EN 60950.
To find the location of the parallel port, please see the Appendix E: Connector Layout chapter.
14.2

C onfiguration

7 2 B
The parallel-port mode, I/O addresses, and IRQs are changeable from the BIOS Setup Utility. You can
program the base I/O-address 378h (default), 3BCh or 278h. You can set the parallel port mode to
disable, enable or AUTO (default). You can choose IRQ5 or IRQ7 as the parallel-port interrupt.
Refer to the I/O Device Configuration Submenu in the Appendix B: BIOS Operation chapter for additional
information on configuration.
Kontron User's Guide
coolMonster/PM
Signal Name
Function
/STB
Strobe
PD0
Data 0
PD1
Data 1
PD2
Data 2
PD3
Data 3
PD4
Data 4
PD5
Data 5
PD6
Data 6
PD7
Data 7
/ACK
Acknowledge
/BUSY
Busy
PE
Paper out
/SLCT
Select out
/AFD
Autofeed
/ERR
Error
/INIT
Init
/SLIN
Select in
VCC *
+ 5 V
GND
Signal Ground
GND
Signal Ground
GND
Signal Ground
GND
Signal Ground
35
14 13BParallel-Port Interface
In / Out
DSUB-25
Out
1
I/O
2
I/O
3
I/O
4
I/O
5
I/O
6
I/O
7
I/O
8
I/O
9
In
10
In
11
In
12
In
13
Out
14
In
15
Out
16
Out
17
--
NC
--
18 - 25
--
18 - 25
--
18 - 25
--
18 - 25