5.3.4 Setting Hydraulic Overload Pressure

The hydraulic overload pressure setting determines the reported hydraulic pressure at which an overload pressure warning
will appear on the cab display module (CDM). This setting can be changed by accessing the OVERLOAD PRESSURE sub-
menu in the WINDROWER SETUP menu.
NOTE:
• This procedure requires the installation of the optional hydraulic pressure sensor kit (MD #B5574). For the appropriate
overload pressure value, refer to the pressure sensor installation instructions supplied with the kit (MD #169031).
• To enable the hydraulic pressure sensor, refer to
To set the hydraulic overload pressure setting:
1. Turn the ignition key to the RUN position, or start the
engine.
2. Press PROGRAM (A) and SELECT (C) simultaneously on the
cab display module (CDM) to enter programming mode.
• WINDROWER SETUP? will appear on the upper line.
• NO/YES will appear on the lower line.
3. Press right arrow (B) to select YES. Press SELECT (C).
• SET KNIFE SPEED? will appear.
4. Press SELECT (D) until OVERLOAD PRESSURE? appears on
the upper line.
• The current overload pressure will appear on lower line.
NOTE:
The range of possible pressure settings is 17,237–
34,474 kPa (2500–5000 psi).
5. Press left arrow (B) or right arrow (C) to configure the
hydraulic overload pressure setting. Press SELECT (D).
6. Press PROGRAM (A) to exit programming mode or press
SELECT (D) to proceed to the next WINDROWER SETUP
option.

5.3.5 Setting Header Index Mode

Enabling header index mode in the cab display module (CDM) links the speed of the reel and the draper on draper headers
to the windrower's ground speed. It can be configured in the CDM by accessing the HEADER INDEX MODE sub-menu in the
WINDROWER SETUP menu.
NOTE:
The header MUST be attached to the windrower to perform this procedure. The cab display module (CDM) automatically
adjusts its programming for each header.
215794
CAB DISPLAY MODULE
5.8.2 Enabling or Disabling Header Sensors, page
EXXX
A
Figure 5.23: CDM Programming Buttons
EXXX
A
Figure 5.24: Hydraulic Overload Pressure
68
105.
WINDROWER SETUP?
CXXX
NO/YES
OVERLOAD PRESSURE?
CXXX
4000 PSI
B
C
B
D
C