1.
Select Enable.
2.
Select People Count to set up the counter.
3.
Draw two detection areas for object counting.
A.
Select Define Detection Zones to define the detection area.
B.
Use the Sensitivity slider to increase or decrease the
detection sensitivity of the area you want to define in step 3C.
The sensitivity levels range from 1 to 10, with 8 as default. The
higher the level, the more sensitive the camera is to motion.
E.
On the live view, outline a detection area. To draw an irregular
shape, drag one or more of the red dots that outline the box
until the line is in the shape that you want. See Figure 4-13.
C.
Click Fix to confirm your setting.
D.
Repeat steps 3A to 3D to draw the 2
detection area is numbered.
E.
To clear any defined area, click
click the X icon to remove it. Click
the setting.
4.
Select Define Object Size to define the size of the target object to be
detected.
A.
On the live view, outline an area matching 5% bigger than the
normal size of the target object. You can drag one or more of
the red dots that outline the area until the line is in the shape
that you want.
B.
Click Fix to confirm your setting.
C.
Move the defined size of object to the place that will not
obstruct the live view.
5.
Select the detection direction from 0 to 1, 0 to 1, or both in Direction
Setting. The object will be counted as 1 when moving through the
first detection area into the second area in the configured direction or
vice versa.
4 4
Administrator Mode
nd
detection area. Each
under the image, and
again to return to
93