EWM L2.00 DC Expert 3.0 TIG Operating Instructions Manual page 31

Control
Table of Contents

Advertisement

Display
099-00L200-EW501
13.05.2022
Setting/selection
Torch cooling menu
Torch cooling mode
-------Automatic operation (ex works)
-------Permanently enabled
-------Permanently disabled
Welding torch cooling, post-flow time
Setting 1–60 min. (ex works 5 min.)
Temperature error limit
Setting 50 - 80°C / 122 - 176°F (factory setting 70°C / 158°F)
Flow monitoring
-------Function disabled
-------Function enabled (factory setting)
Flow error limit
Setting 0.5 l - 2.0 l / 0.13 gal - 0.53 gal (factory setting 0.6 l / 0.16 gal)
Service menu
Any changes to the service menu should be agreed with the authorised service person-
nel.
Show warnings > see 7.1 chapter
-------Function disabled (ex works)
-------Function enabled
Fuse protection warning
-------Function disabled (factory setting)
-------Function enabled
Dynamic power adjustment > see 5.9 chapter
Special parameters menu
Non-latched operation (version C) > see 5.1.7.6 chapter
-------Function enabled
-------Function disabled (ex works)
Welding current actual value display > see 4.3 chapter
-------Actual value display
-------Nominal value display
Pulsed TIG welding (thermal)
-------Function enabled (ex works)
-------For special applications only
TIG antistick > see 5.1.9 chapter
-------function active (factory setting).
-------function inactive.
Average value controller (AC)
-------Function enabled (factory setting)
-------Function disabled
activArc voltage measuring
-------Function enabled (ex works)
-------Function disabled
Error output to interface for automated welding, contact SYN_A
-------AC synchronisation or hot wire (ex works)
-------Error signal, negative logic
-------Error signal, positive logic
-------AVC (Arc voltage control) connection
1