EVM Setup and Quick Start Guide
2 EVM Setup and Quick Start Guide
Default EVM Configuration
The TPS7H5001/2/3/4EVM-CVAL can be quickly turned on and run using the connections shown in
TPS7H5001EVM-CVAL
Connections.
Terminal or Test Point
J11 (VIN)
TP9 (COMP)
Positive and Negative Terminal for J11
positive input voltage to the positive terminal and GND to negative terminal.
4
TPS7H500x-SP Evaluation Module User's Guide
lists the default configuration.
Table 2-1. Default EVM Configuration
Parameter
Input Power Supply
Operating Temperature
Switching Frequency
Table 2-2. TPS7H5001/2/3/4EVM-CVAL Connections
Voltage Source
4 to 14-V input at 10 mA. See Positive and Negative Terminal for J11 for
connections.
1 V at < 10 mA (input range can be –0.3 V to 3.3 V based on the
TPS7H5001-SP Radiation-Hardness-Assured Si and GaN Dual Output
Controller data
sheet)
shows which terminal is the positive and negative on J11. Connect the
Figure 2-1. Positive and Negative Terminal for J11
Copyright © 2022 Texas Instruments Incorporated
Specification
4 V to 14 V
25°C
500 kHz
SLVUCD0 – FEBRUARY 2022
Submit Document Feedback