BQ76952 EVM Quick Start Guide

2 BQ76952 EVM Quick Start Guide

2.1 Before You Begin

The following warnings and cautions are noted for the safety of anyone using or working close to the BQ76952
EVM. Observe all safety precautions.
!
The default settings of the BQ76952 do not limit performance to the ratings of the EVM. Set all
protections appropriately and limit current for safe operation.
The circuit module has signal traces, components, and component leads on the bottom of the board.
This may result in exposed voltages, hot surfaces or sharp edges. Do not reach under the board
during operation.
The circuit module may be damaged by over temperature. To avoid damage, monitor the
temperature during evaluation and provide cooling, as needed, for your system environment. Do not
operate beyond the current and voltage limits in the Sepcification Table.
Some power supplies can be damaged by application of external voltages. If using more than 1
power supply, check your equipment requirements and use blocking diodes or other isolation
techniques, as needed, to prevent damage to your equipment.
The communication interface is not isolated on the EVM. Be sure no ground potential exists between
the computer and the EVM. Also be aware that the computer is referenced to the Battery- potential
of the EVM.
Connections for rated current must be made at the terminal block. Test points are not rated for the
board current.
4
BQ76952 Evaluation Module
Warning
The BQ76952EVM circuit module may become hot during operation due to
dissipation of heat. Avoid contact with the board. Follow all applicable safety
procedures applicable to your laboratory.
Warning
The bq76952EVM is not rated as a high voltage EVM, has smaller clearances than
normally used on high voltage boards and does not have an isolation boundary. If
you apply high voltage to this board, all terminals should be considered high
voltage. Electric shock is possible when connecting the board to live wire. The
board should be handled with care by a professional. For safety, use of isolated
test equipment with overvoltage and overcurrent protection is highly recommended.
Caution
Do not leave the EVM powered when unattended.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION