3 Software

3.1 Quick Start Setup

Figure 3-1. TMAG3001EVM With A1 and A2 Still Joined Together
To set up and use the EVM, follow these steps:
1. Gently flex the panel at the score line shown in
factor. This split provides separate boards for the TMAG3001A1 and TMAG3001A2 portions of the original
board.
2. Download and install the driver as a one-time step per PC: https://www.ti.com/tool/download/SBAC253.
3. Attach the EVM to the Sensor Control Board (SCB). To evaluate the TMAG3001A1 on the EVM, attach
header J1 of the Sensor Controller board to header J1_A1 of the EVM (see
TMAG3001A2 on the EVM, attach header J1 of the Sensor Controller board to header J1_A2 of the EVM
(see
Figure
3-3).
4. Use a USB cable to connect the SCB to a PC:
a. Insert the micro USB cable into the USB receptacle J2 that is on the SCB Controller onboard.
b. Plug the other end of the USB cable into a PC.
5. Access the GUI in either the Google Chrome
dev.ti.com/gallery/view/PositionSensing/TMAG3001EVM_GUI/ver/1.0.0/.
6. To quickly view results on the GUI, do the following:
a. Modify the MAG_CH_EN bits in the SENSOR_CONFIG_1 register to enable the desired channels
to read from. The GUI has drop-down boxes to configure these bits when the SENSOR_CONFIG_1
register is selected in the register tab of the GUI.
b. Select the desired result plots under the Results to collect/show box in the Results Data tab, and press
Collect Data to trigger the read.
These two steps are the minimum steps needed to see results in the GUI. However, this assumes that the
default register settings are used for the other registers. For more custom settings, modify the corresponding
register bits according to the system requirements.
7. Apply a magnetic field to the sensor by doing one of the following:
a. Wave the included hand held magnet around the sensor.
b. Attach the Rotate & Push module to the EVM (see
modules, see
Section
8. Observe the outputs in the GUI. See
3.2 EVM Operation
Figure 3-2
and
Figure 3-3
SLYU066 – OCTOBER 2023
Submit Document Feedback
Figure 3-1
®
or Firefox
3.2.2.
Section 3.2.1.3
show how to connect the EVM to the included SCB.
Copyright © 2023 Texas Instruments Incorporated
to split the board in half for a more compact form
Figure
®
browser by clicking on the following link:
Figure
3-12). For more details on how to use these
for more information on GUI setup and operation.
Software
3-2). To evaluate the
https://