Bq76942 Evm Quick Start Guide; Before You Begin; Quick Start - Texas Instruments BQ76942EVM User Manual

Table of Contents

Advertisement

BQ76942 EVM Quick Start Guide

2 BQ76942 EVM Quick Start Guide

2.1 Before You Begin

The following warnings and cautions are noted for the safety of anyone using or working close to the BQ76942
EVM. Observe all safety precautions.
!
The default settings of the BQ76942 do not limit performance to the ratings of the EVM. Set all
protections appropriately and limit current for safe operation.
The circuit module has signal traces, components, and component leads on the bottom of the board.
This may result in exposed voltages, hot surfaces or sharp edges. Do not reach under the board
during operation.
The circuit module may be damaged by over temperature. To avoid damage, monitor the
temperature during evaluation and provide cooling, as needed, for your system environment. Do not
operate beyond the current and voltage limits in the Sepcification Table.
Some power supplies can be damaged by application of external voltages. If using more than 1
power supply, check your equipment requirements and use blocking diodes or other isolation
techniques, as needed, to prevent damage to your equipment.
The communication interface is not isolated on the EVM. Be sure no ground potential exists between
the computer and the EVM. Also be aware that the computer is referenced to the Battery- potential
of the EVM.
Connections for rated current must be made at the terminal block. Test points are not rated for the
board current.

2.2 Quick Start

The BQ76942 registers must be configured to enable most protections, select the monitored cells, and enable
the protection FETs on the EVM. This quick start section does not describe current protection settings. Once all
registers are configured, the values may be written to One Time Programmable memory (OTP) for use on the
next reset of the device, but since that is a permanent change it is not part of this quick start procedure. This
4
BQ76942 Evaluation Module
Warning
The BQ76942EVM circuit module may become hot during operation due to
dissipation of heat. Avoid contact with the board. Follow all applicable safety
procedures applicable to your laboratory.
Caution
Do not leave the EVM powered when unattended.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
Copyright © 2020 Texas Instruments Incorporated
SLUUC32A – NOVEMBER 2019 – REVISED OCTOBER 2020
Submit Document Feedback
www.ti.com

Advertisement

Table of Contents