2 EVM Setup and Quick Start Guide

Default EVM Configuration
The TPS7H5001-SP can be quickly turned on and run using the connections shown in
Connections.
Terminal or Test Point
J11 (VIN)
TP9 (COMP)
Positive and Negative Terminal for J11
positive input voltage to the positive terminal and GND to negative terminal.
SLVUBZ8 – JULY 2021
Submit Document Feedback
lists the default configuration.

Table 2-1. Default EVM Configuration

Parameter
Input Power Supply
Operating Temperature
Switching Frequency

Table 2-2. TPS7H5001-SP Connections

Voltage Source
4 to 14 V input at 10 mA, See Positive and Negative Terminal for J11 for
connections
1 V at < 10 mA (Input range can be –0.3 V to 3.3 V based on the
TPS7H5001-SP Radiation-Hardness-Assured Si and GaN Dual Output
Controller
data sheet)
shows which terminal is the positive and negative on J11. Connect the

Figure 2-1. Positive and Negative Terminal for J11

Copyright © 2021 Texas Instruments Incorporated
EVM Setup and Quick Start Guide
Specification
4 V to 14V
25°C
500 kHz