ICP DAS USA tM-7565 User Manual page 50

The uart to can bus converter
Hide thumbs Also See for tM-7565:
Table of Contents

Advertisement

BB
0D
0E
 Response: A valid command will let the module to apply the RS-232/RS-485/RS- 422/USB
configuration parameters.
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the "Error Response" function in the CAN Converter Utility, in order to
receive Syntax and/or communication error information at the host PC.
This function is just supported by the firmware version 3.00 or more in I-7530 series and
I-7565. The tM-7530, tM-7530A, and tM-7565 is always supported.
 Example:
Command: P20B30000<CR>
The module's RS-232/RS-485/RS-422/USB configuration will be changed to the
rate=115.2K, data bit=8, stop bit=1, none parity, no checksum and no error responses. When
CAN Converter module was rebooted, the RS-232/RS-485/RS-422/USB parameter will be
recovered to the previous setting.
I-7530, I-7530-FT, I-7530A, I-7565, tM-7530, tM-7530A, tM-7565 User Manual Version 1.5
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved
and tM-7565.
460800 bps baud rate of RS-232, only for I-7565
921600 bps baud rate of RS-232, only for I-7565