ICP DAS USA tM-7565 User Manual page 47

The uart to can bus converter
Hide thumbs Also See for tM-7565:
Table of Contents

Advertisement

BB
0D
0E
 Response: A valid command will let the module write the RS-232/RS-485/RS-422/USB
parameters into the EEPROM and then reboot the system.
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the "Error Response" function in the CAN Converter Utility, in order to
receive Syntax and/or communication error information at the host PC.
I-7565 supports only one 921600 baud rate on the firmware version 2.X or before.
 Example:
Command: P00B30000<CR>
Set the RS-232/RS-485/RS-422/USB baud rate=115.2K, data bit=8, stop bit=1, none parity,
no checksum and No error responses into the CAN Converter module and then reboot the
CAN Converter module.
I-7530, I-7530-FT, I-7530A, I-7565, tM-7530, tM-7530A, tM-7565 User Manual Version 1.5
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved
and tM-7565
460800 bps baud rate of RS-232, only for I-7565
921600 bps baud rate of RS-232, only for I-7565
Description
E-mail: service@icpdas.com
47