Parker 514C Product Manual page 18

Dc controller
Hide thumbs Also See for 514C:
Table of Contents

Advertisement

2-6
Pre-Installation Planning
Auxiliary Supply Terminals
TERMINAL
FUNCTION
A1
AC Supply
Contactor Coil.
A2
AC Supply
Contactor Coil.
A3
Auxiliary AC Supply
Neutral.
A4
Auxiliary AC Supply
Live.
Power Terminals
TERMINAL
FUNCTION
L1
AC Input Line 1
L2/N
AC Input Line 2/
Neutral
A+
Armature Positive
A-
Armature Negative
Ground
Field Terminals
TERMINAL
FUNCTION
F-
Field Negative
F+
Field Positive
FL2
Field Rectifier Supply Mains Supply Input Field Rectifier
FL1
Field Rectifier Supply Mains Supply Input Field Rectifier
DESCRIPTION
AC Supply to AC Supply
Contactor Switched Live.
AC Supply to AC Supply
Contactor Neutral.
Auxiliary Supply for Power
Supplies and Contactor.
Auxiliary Supply for Power
Supplies and Contactor.
DESCRIPTION
Mains Supply Line 1 Input
Mains Supply Line 2 Input or
Neutral
Motor Armature Positive Output.
Motor Armature Negative
Output.
DESCRIPTION
Motor Field Negative DC Output
Motor Field Positive DC Output
NOTES
540/1 Terminal D12
540/1 Terminal D11
540/1 Terminal D10
540/1 Terminal D9
NOTES
L1
L2/N
A+
A-
NOTES
540/1 Terminal D7
540/1 Terminal D5
540/1 Terminal D3
540/1 Terminal D1
514C Product Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

514c-04514c-08514c-16514c-32Dc514c

Table of Contents