Terminal Descriptions - Parker 514C Product Manual

Dc controller
Hide thumbs Also See for 514C:
Table of Contents

Advertisement

2-2
Pre-Installation Planning

TERMINAL DESCRIPTIONS

Control Terminals
TERMINAL
FUNCTION
T1
Tacho Feedback
T2
Not Connected
T3
Speed Meter Output Analogue Output,
T4
DO NOT USE
T5
Run Input
T6
Current Meter
Output
T7
Torque/Current
Limit Input
T8
0V Common
T9
Setpoint Ramp
Output
T10
Positive Trim Speed
Setpoint Input
T11
0V Common
T12
Total Setpoint Sum
Output
T13
Setpoint Ramp Input Analogue Input,
T14
+10V Reference
Output
T15
Stall Override Input Digital Input to Override Stall Detection
T16
-10V Reference
Output
T17
Negative Trim
Speed Setpoint
Input
DESCRIPTION
Motor Mounted Tachogenerator Input.
Proportional to Motor Speed.
0 to 10V for 0 to 100% Speed.
Pending Change.
Digital Input to Run Controller.
+24V to Run.
0V to Stop.
Analogue Output, 0 to +7.5V =
150% Calibrated Current
SW1/5 Off = Bipolar
SW1/5 On = Magnitude
Analogue Input,
0 to +7.5V = 0 to 150% of Calibrated
Current.
Analogue / Digital Signal Common
Analogue Output,
0 to 10V = 0 to 100% Ramped
Setpoint.
Analogue Input,
0 to 10V = 0 to 100% Speed.
Analogue / Digital Signal Common.
Analogue Output,
0 to 10V = 0 to 100% Speed.
0 to +10V = 0 to 100% Forward
Speed.
0 to -10V = 0 to 100% Reverse Speed.
Analogue Output,
+10V Reference for Speed/ Current
Setpoints.
+10V = Override.
Analogue Output,
-10V Reference for Speed/ Current
Setpoints.
Analogue Input,
0 to +10V = 0 to 100% Reverse Speed
0 to -10V = 0 to 100% Forward Speed.
NOTES
+350 Vdc Max. Approx
220 kohm.
5mA output
S/C protected
5mA output
S/C protected
approx.
100 kohm
5mA output
S/C protected
approx.
100 kohm
5mA output
S/C protected
approx.
100 kohm
5mA output
S/C protected
approx.
100 kohm
5mA output
S/C protected
approx.
100 kohm
514C Product Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

514c-04514c-08514c-16514c-32Dc514c

Table of Contents