Catalog 0700P-5/USA
Proportional Regulator Applications .................... B4-B5
Why Proportional Technology? .................................. B6
Ordering Information ................................................. B7
Options ...................................................................... B8
Technical Information......................................... B9-B11
P3KNA AVAILABLE JULY 1, 2008
"P3HPA" / "P3KNA" Series
Electronic Proportional Regulators
"P3HPA" / "P3KNA"
Series
Electronic Proportional Regulator
0 to 10 volt, 4 to 20 mA
Programming Information ................................ B12-B18
Dimensions .............................................................. B19
Troubleshooting ....................................................... B20
Glossary .................................................................. B21
B3
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
A
B
C
D
E
F
G
H
J
K
L
M

Advertisement

loading
Need help?

Need help?

Do you have a question about the P3HPA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker P3HPA Series

  • Page 1: Table Of Contents

    Proportional Regulator Applications ....B4-B5 Dimensions .............. B19 Why Proportional Technology? ........B6 Troubleshooting ............B20 Ordering Information ..........B7 Glossary ..............B21 Options ..............B8 Technical Information......... B9-B11 P3KNA AVAILABLE JULY 1, 2008 Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 2 Suitable for Washdown: IP65 Forced Exhaust Compact and Light Weight Small Envelope Light Weight Flexible Mounting Options Stand-alone Outstanding Performance Foot Bracket Mounting Very Fast Response Times DIN-Rail Mounting Full Flow Exhaust Excellent Linearity Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 3: Proportional Regulator Applications

    “body-in-white” lines. The control of clamping and welding forces during panel assembly is an ideal application, also accurate control in paint dipping and spraying can be achieved. Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 4: Why Proportional Technology

    Also, no account is taken of external influences such as air consumption by the system, which can drastically alter the actual value. Typical Application in Automotive Body in White Welding Pressure Control Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 5: Ordering Information

    Parameter 8. P3HPA / P3KNA Kits Seal Kit (Valve Seat, Cover Seal) ......3538200 Valve Kit (2 Valves, Screws, Cover Seal) ....3538100 Cable (M12, 4-Pin Female Connection with 2m Cable) ..........CB-M12-4P-2M Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 6 Order Code Description Order Code Description P3HKA00MK P3KKA00ML DIN Rail Mounting Kit L-Bracket Mounting Kit P3HKA00MF P3KKA00MC Foot Bracket Mounting Kit Foot Bracket Mounting Kit DIN Rail Foot Bracket L-Bracket Foot Bracket Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 7: Technical Information

    Blue The factory setting is as indicated on the label, can be 24 V Alarm Output Signal Black changed through the software at all times (parameter 14). 24 VDC Schematic Control Signal Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 8 Standard Version ............Brass Food .............Stainless Steel Seats and Auxiliary Piston ......Delrin, Brass Solenoid Valve Housing ......Techno Polymer Solenoid Valve Poppet ..........FPM Remaining Seals ............NBR Valve ..............Polyurethane Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 9 P2 = 72.5 PSIG Pressure Drop @ 14.5 PSIG = 191.8 SCFM 72.5 P2 = 43.5 PSIG Pressure Drop @ 14.5 PSIG = 203.6 SCFM 43.5 P2 = 14.5 PSIG Pressure Drop @ 14.5 PSIG = N/A SCFM 14.5 Flow (SCFM) Flow (I/sec) Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 10: Programming Information

    If other than 3, Accepts and Accesses use Up or Down saves new changeable Accesses Displays current Arrow and parameter Sequences to parameters. parameter no. 0. parameter value. accept 3 setting. next parameter. Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 11 P3H (NPN or PNP) saves new changeable Accesses with analog 1 = analog 0..10V parameter Sequences to parameters. parameter no. 6. options 2 = analog 4..20 mA setting. next parameter. Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 12 Description the display Accepts and value if using an Accesses saves new external pressure changeable Accesses Displays current parameter Sequences to parameters. parameter no. 9. digital display sensor. setting. next parameter. Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 13 2 mbar x % P19 Accesses saves new changeable Accesses 10 bar unit: parameter Sequences to parameters. parameter no. 18. x 10 mbar x % P19 Edits parameter. setting. next parameter. Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 14 20. parameter value. band is broad) setting. next parameter. * When the value 0 is entered, you are able to create your own custom settings true parameters 12, 13 and 21. Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 15 4 and 40) Flashing Displays current parameter value. Accepts and Description Accesses Incremental saves new changeable Accesses value is parameter Sequences to parameters. parameter no. 13. x 10 mbar Edits parameter. setting. next parameter. Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 16 Parameter Number 39 – Displays Current Software Version Step Press 3-6 seconds Until Display Reads Flashing Decimal Displays current Accesses parameter value. Description changeable Accesses XXX = current parameters. parameter no. 39. software version Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 17: Dimensions

    (56) (26) 2.05 (0.83) (52) DIN-Rail Clamp 0.35 Ø 0.87 2.05 1.57 (22) (52) (40) Ø .28 1.83 1.65 4 Holes (46.6) (42) 3.31 (84) 3.94 Dimensions are in mm (Inches) (100) Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 18 Wrong setpoint value given in relation to Change over setpoint value to either V or mA programmed setpoint value acceptance or Reprogram the unit to the correct setpoint value via parameter 4 Any other problem Please consult factory Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 19: Glossary

    PNP Output – Referred to as a “Sourcing” open collector transistor output where the voltage sources towards 24VDC when activated. NPN Output – Referred to as a “Sinking” open collector transistor output. The output sinks towards 0VDC when activated. Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics...
  • Page 20 1.4. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs or Vacuum products. Do not select, or use Parker valves, FRLs or vacuum products without thoroughly reading and understanding this safety guide as well as the specific Parker publications for the products considered or selected.
  • Page 21 Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling 1-800-CPARKER, or by accessing the Parker web site at www.parker.com.
  • Page 22 The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized distributors, are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries and its authorized distributors.