Function Block Descriptions

Note: To view all parameters available on the MMI, Full menu detail must be selected in the

Understanding the Function Block Description

Note: The "Range" for a parameter value is given in the Parameter Description Table on each
650G Software Product Manual
DETAILED MENUS parameter (
the Comms.
The following function
blocks show the parameter
information necessary for
programming the drive.
Input parameters are shown
on the left hand side, and
output parameters are shown
on the right hand side of the
block.
The diagrams assume that the
UK country code is selected
and that a 400V 11kW Frame
C power board is fitted. This
is reflected in the values of
certain parameters, see "*"
and "**" in the table below.
Instance Name
Names the function block and MMI menu
Default Value
The default value of the unmodified macro, Macro 0
Input/Output
The name shown on DSE
Parameter Name
Tag Number
Unique identification used for communications
*
Parameters marked with "*" are set to a value depending upon the
"operating frequency" of the drive. Refer to Chapter 2: "Parameter
Specification" - Frequency Dependent Defaults; and the Installation
Product Manual, Chapter 5: "The Operator Station" - Changing the
Product Code (3-button reset).
**
Parameters marked with "**" are set to a value depending on the overall
"power build " of the drive indicated by the product code. Refer to
Chapter 2: "Parameter Specification" - Power Dependent Defaults; and the
Installation Product Manual: Chapter 2: "Understanding the Product
Code".
Function Block page. Ranges for outputs are given as "—.xx %", for example, indicating
an indeterminate integer for the value, to two decimal places.
Parameters indicated with
F
MENUS parameter (
M
Parameters indicated with
Application using parameter
VF
Parameters indicated with
motor control mode, as selected by parameter
SV
Parameters indicated with
Vector) motor control mode, as selected by parameter
Programming Your Application
ST
99). Additional blocks/parameters are available over
Instance Name
Default Value
100.00 % – [ 14] SCALE
0.00 % – [ 15] OFFSET
0..+10 V – [ 13] TYPE
Tag Number
Figure Chapter 1-1 Function Block Parameter Information
F
are visible with Full menus only. Refer to the DETAILED
ST
99) in the MMI ACCESS function block, page 1-42.
M
are Motor Parameters. They are not reset by changing
P
1; all other parameters are reset to default values.
VF
are only visible when the drive is in VF (Volts/Hz)
S
SV
are only visible when the drive is in SV (Sensorless
Output Parameter
Name
Analog Input 1
VALUE
[ 16] – 0.0 %
Default Value
Input Parameter
Name
CL01.
S
CL01.
1-3

Advertisement

Table of Contents
loading

Table of Contents