Light Source/Temperature Indicators; When An Indicator Lights Up - Panasonic PT-JX200GWU Operating Instructions Manual

Table of Contents

Advertisement

Chapter 6 Maintenance — Light source/temperature indicators

Light source/temperature indicators

When an indicator lights up

If a problem should occur inside the projector, the light source indicator <LIGHT>/temperature indicator <TEMP>
will inform you by lighting or blinking. Check the status of the indicators and remedy the indicated problems as
follows.
Attention
f Make sure to turn off the power before performing the procedure.
f Make sure to follow the procedure in "Turning off the projector" (x page 50) when switching off the projector.
f Check the status of the power supply with the power indicator <ON (G)/STANDBY (R)>. (x page 46)
Light source indicator <LIGHT>
Indicator status
The light source may not light
Status
properly.
Cause
Solution
Turn off the power supply of the track system, and then turn on the power again.
Note
f If the light source indicator <LIGHT> is still lighting or blinking after taking above measures, ask your dealer for repair.
f When the device is projecting and no light is lighting or blinking in red, the light source indicator <LIGHT> will light in green.
Temperature indicator <TEMP>
Indicator status
Status
Internal temperature is high (warning).
f Is the air intake/exhaust port blocked?
Cause
f Is the room temperature high?
f Remove any objects that are blocking the air intake/exhaust port.
f Install the projector in a location with the operating environment temperature
Solution
between 0 °C (32 °F) and 40 °C (104 °F)
f Do not use the projector at high altitudes of 2 700 m (8 858') or higher
above sea level.
*1 The operating environment temperature should be between 0 °C (32 °F) and 35 °C (95 °F) when using the projector at elevations between 1 000 m
(3 281') and 2 700 m (8 858') above sea level.
Note
f If the temperature indicator <TEMP> is still lighting or blinking after taking above measures, ask your dealer for repair.
134 - ENGLISH
ON(G)/
STANDBY(R)
LIGHT
TEMP
SD
Lighting in red
(projecting)
The light source does not light or is suddenly turned off.
Lighting in red
Internal temperature is high (standby
status).
Power indicator <ON (G)/STANDBY (R)>
Light source indicator <LIGHT>
Temperature indicator <TEMP>
Blinking in red
(2 times)
Blinking in red
(2 times)
.
*1
Blinking in red
(3 times)
Blinking in red
(3 times)
The internal cooling fan is not running.
f Turn off the power supply of the
track system, and then consult your
dealer.