[Lens Calibration]; [Lens Memory] - Panasonic PT-RQ13K Operating Instructions Manual

Hide thumbs Also See for PT-RQ13K:
Table of Contents

Advertisement

[PROJECTION METHOD]
4)
Press the <ENTER> button.

[LENS CALIBRATION]

Detect the lens shift limit value of the projector and set the home position and the ET-D75LE90 lens standard
position automatically.
1)
Press as to select [LENS CALIBRATION].
2)
Press qw to switch the item.
f The items will switch each time you press the button.
[NORMAL]
[D75LE90]
3)
Press the <ENTER> button.
f The confirmation screen is displayed.
4)
Press qw to select [OK], and press the <ENTER> button.
f To cancel, select [CANCEL].
f The lens moves up, down, left, and right to detect the lens shift limit value, and automatically set the home
position and the ET-D75LE90 lens standard position.
f The lens stops to complete the calibration.
Note
f [PROGRESS] is displayed in the menu during lens calibration. The operation cannot be canceled during calibration.
f When lens calibration executes correctly, [COMPLETE] is displayed and [INCOMPLETE] is displayed when it does not execute correctly.
f Pressing the <FOCUS> button on the remote control for at least three seconds will also display the confirmation screen for lens calibration
execution.

[LENS MEMORY]

Save and load the focus position, shift position, and zoom position of an adjusted lens.
Saving lens position
1)
Press as to select [LENS MEMORY].
2)
Press the <ENTER> button.
3)
Press as to select [LENS MEMORY SAVE].
4)
Press the <ENTER> button.
f The [LENS MEMORY SAVE] screen is displayed.
5)
Press as to select the item to save, and press the <ENTER> button.
6)
When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
f The [LENS MEMORY NAME INPUT] screen is displayed.
7)
Press asqw to select the text, and press the <ENTER> button to enter the text.
8)
After the name is input, press asqw to select [OK], and press the <ENTER> button.
f The registration completes and returns to the [LENS MEMORY SAVE] screen.
f If you press asqw to select [CANCEL] and then press the <ENTER> button, the lens memory will not be
saved.
f If you press asqw to select [DEFAULT] and press the <ENTER> button, the entered name will not be
registered and the default name will be used.
f If you select [OK] without entering any characters and press the <ENTER> button, the default name will be
used.
144 - ENGLISH
Chapter 4 Settings — [PROJECTOR SETUP] menu
Switches the [PROJECTION METHOD] setting. (x page 128)
Select this item when anything other than the Fixed-focus Lens (Model No.: ET-D75LE90) is used.
Move the lens to the home position after completing the calibration.
Select this item when the Fixed-focus Lens (Model No.: ET-D75LE90) is used.
Move the lens to the ET-D75LE90 lens standard position after completing the calibration.