Standard status
Only [KEYSTONE] used
Projection
Vertical
lens Model
keystone
No.
correction
angle α (°)
ET-D75LE6
±28
ET-D75LE8
±40
ET-D75LE10
±40
ET-D75LE20
±40
ET-D75LE30
±40
ET-D75LE40
±40
ET-D75LE50
±22
ET-D75LE90
+5 / -0
*2
*1 When [VERTICAL KEYSTONE] and [HORIZONTAL KEYSTONE] are used simultaneously, correction cannot be made exceeding total of 30°.
*2 Only the vertical keystone correction angle can be corrected in the direction in which the projector body moves away from the screen.
When using the optional Upgrade Kit (Model No.: ET-UK20)
Only [KEYSTONE] used
Projection
Vertical
lens Model
keystone
No.
correction
angle α (°)
ET-D75LE6
±28
ET-D75LE8
±45
ET-D75LE10
±40
ET-D75LE20
±40
ET-D75LE30
±45
ET-D75LE40
±45
ET-D75LE50
±22
ET-D75LE90
+5 / -0
*2
*1 When [VERTICAL KEYSTONE] and [HORIZONTAL KEYSTONE] are used simultaneously, correction cannot be made exceeding total of 30°.
*2 Only the vertical keystone correction angle can be corrected in the direction in which the projector body moves away from the screen.
Note
f When [GEOMETRY] is used, the focus of the entire screen may be lost as correction increases.
f Make the curved screen a circular arc shape with one part of a perfect circle removed.
f Adjustment range of the [GEOMETRY] items may not match the listed projection range depending on the projection lens. Use this projector
within the projection range, otherwise the correction may not work.
f The expansion function by applying the optional Upgrade Kit (Model No.: ET-UK20) cannot be used when the video signal in simultaneous
format is input.
Chapter 2 Getting Started — Setting up
[KEYSTONE] and [CURVED] used together
*1
Horizontal
Vertical
keystone
keystone
correction
correction
angle β (°)
angle α (°)
±15
±10
±15
±20
±15
±10
±15
±15
±15
±20
±15
±20
±15
±8
0
[KEYSTONE] and [CURVED] used together
*1
Horizontal
Vertical
keystone
keystone
correction
correction
angle β (°)
angle α (°)
±15
±10
±40
±20
±15
±10
±20
±15
±25
±20
±30
±20
±15
±8
0
Horizontal
keystone
Min. value of
Min. value of
correction
R2/L2
angle β (°)
±10
1.6
±15
0.2
±10
1.1
±10
0.9
±10
0.6
±15
0.4
±8
2.0
Horizontal
keystone
Min. value of
correction
R2/L2
angle β (°)
±10
1.2
±15
0.2
±10
0.9
±10
0.7
±10
0.5
±15
0.3
±8
1.5
Only [CURVED] used
*1
Min. value of
R3/L3
R2/L2
3.9
0.9
0.4
0.2
2.6
0.6
1.7
0.5
1.2
0.4
0.7
0.2
4.9
1.2
Only [CURVED] used
*1
Min. value of
Min. value of
R3/L3
R2/L2
3.0
0.7
0.3
0.1
2.0
0.5
1.3
0.4
0.9
0.3
0.5
0.2
3.7
0.9
ENGLISH - 39
Min. value of
R3/L3
2.3
0.3
1.5
1.0
0.7
0.4
2.9
Min. value of
R3/L3
1.7
0.2
1.1
0.7
0.5
0.3
2.2