Specifications - Panasonic PT-RQ13K Operating Instructions Manual

Hide thumbs Also See for PT-RQ13K:
Table of Contents

Advertisement

Specifications

The specifications of the projector are as follows.
Power supply
Power consumption
Size
DLP chip
Display system
Number of pixels 4 096 000 pixels (2 560 x 1 600 dots)
Lens
Light source
Light output
*1
Contrast ratio
*1
Projected image size
Image aspect ratio
Projection method
Power cord length
Outer case
Width
Dimensions
Height
Depth
Weight
Noise level
*1
Operating
environment
temperature
Operating
environment
Operating
environment
humidity
Power supply
Operating range
Remote
control
Weight
Dimensions
*1 Measurement, measuring conditions and method of notation all comply with ISO21118 international standards.
*2 When the Zoom Lens (Model No.: ET-D75LE8) is used, the projected image size for the maximum projection distance will be 1.78 m (70") to
15.24 m (600"). When the Fixed-focus Lens (Model No.: ET-D75LE90) is used, the projected image size for the maximum projection distance will be
3.05 m (120") to 15.24 m (600").
*3 Average value. Weight varies for each product.
*4 The operating environment temperature should be between 0 °C (32 °F) and 40 °C (104 °F) if the projector is used at an altitude between 1 400 m
(4 593') and 4 200 m (13 780') above sea level. When the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] is
set to [ECO], [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3], the operating environment temperature should be between 0 °C (32 °F) and 40 °C
(104 °F), regardless of the altitude. When the Smoke Cut Filter is used, the operating environment temperature should be between 0 °C (32 °F) and
35 °C (95 °F).
When the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] is set to [ECO], [LONG LIFE1], [LONG LIFE2], or
[LONG LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level. When the Smoke Cut Filter is used, the
projector cannot be used at an altitude of 1 400 m (4 593') or higher above sea level.
*5 When the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] is set to [NORMAL], and the operating environment
temperature exceeds the following value, the light output may be reduced to protect the projector.
f When using the projector at an altitude lower than 2 700 m (8 858') above sea level: 35 °C (95 °F)
f When using the projector at an altitude between 2 700 m (8 858') and 4 200 m (13 780') above sea level: 25 °C (77 °F)
When the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] is set to [ECO], [LONG LIFE1], [LONG LIFE2], or
[LONG LIFE3], and the operating environment temperature exceeds 35 °C (95 °F), the light output may be reduced to protect the projector.
Note
f The light output will decrease as much as the power supply voltage is decreased. It is recommended to use with AC 200 V or higher to
prioritize luminance.
216 - ENGLISH
Chapter 6 Appendix — Specifications
100 V - 240 V ~ (100 V - 240 V alternating current), 50 Hz/60 Hz
1 270 W (12.0 A - 6.0 A)
When [STANDBY MODE] is set to [ECO]: 0.3 W
When [STANDBY MODE] is set to [NORMAL]: 4 W
22.9 mm (0.90") (aspect ratio 16:10)
DLP chip x 3, DLP projection system
Optional
Laser, 2-bank type
10 000 lm (ANSI)
20 000:1 (when [DYNAMIC CONTRAST] is set as [3])
1.78 m (70") to 25.40 m (1 000")
16:10
[FRONT/CEILING], [FRONT/FLOOR], [REAR/CEILING], [REAR/FLOOR]
3.0 m (118-1/8")
Molded plastic
578 mm (22-3/4")
270 mm (10-5/8") (excluding the feet)
725 mm (28-17/32") (excluding the protrusion)
Approx. 49.0 k] (108.0 lbs.)
*3
46 dB
0 °C (32 °F) to 45 °C (113 °F)
*4 *5
10 % to 80 % (no condensation)
DC 3 V (AA/R6/LR6 battery x 2)
Within approx. 30 m (98'5") (when operated directly in front of signal receiver)
150 ] (5.3 ozs.) (including batteries)
Width: 47.5 mm (1-7/8"), Height: 181.5 mm (7-5/32"), Depth: 27.5 mm (1-3/32")