5-20
Measurement tasks
* e.g. shock pulse value + envelope +
velocity spectrum
Result display (left)
Evaluation (right)
Status / evaluation icons
Alarm
Warning
Prewarning
Measuring
Measured
Error

Multi-measurement task ('Multitask')

A multi-measurement task shortens the measurement times by
combining several, similar measurement tasks*. It is particularly
time-saving in the case of measurement tasks that are measured
at the same measurement location with the same transducer and
the same filter settings. In this case, VIBXPERT only carries out one
signal measurement and calculates the results of the individual
measurement tasks from this.
Initially, no measurement results appear in the Results screen, just
information on the status of the measurement together with the
assessment of the results (see below).
Evaluating the results
The evaluation of the results is carried out on the basis of the stored
thresholds. If a threshold is exceeded, the corresponding symbol
appears in the 'Status' column (see below left).
• For a detailed view of the evaluation scale, press the MENU key
and click on 'Evaluation Overview' (see below).
Result of the single measurements
• After the measurement, press a navigation key until a black
frame appears around the list field.
• Press 'Enter' to activate the list field.
• Click on the measurement in the list whose result is to be
displayed.
• Press ESC to return to the list field.
Multitask