Temperature Measurement - Fluke VIBXPERT II User Manual

Data collector & vibration analyzer
Hide thumbs Also See for VIBXPERT II:
Table of Contents

Advertisement

Temperature measurement

For temperature measurements thermocouple type K sensors such
as the VIB 8.608 handheld probe can be used.
Tips for measuring
- Hold the sensor at the measurement location until the sensor has
recorded the temperature of the measurement object.
- If the values vary, repeat the measurement or increase the
number of averages in the measurement setup.
- VIBXPERT does not carry out any sensor detection on the
measurement channel for temperature. If the results are not
correct, check the connection and the sensor cable.
B
A
Hand-held temperature probe -
VIB 8.608
Measurement tasks
Measurement range:
VIB 8.608: -50°C to 500°C
Temperature probes
(Type K thermocouple, technical data
are given in the sensor catalog)
5-5