Measuring Vibcode Route/ Pool - Fluke VIBXPERT II User Manual

Data collector & vibration analyzer
Hide thumbs Also See for VIBXPERT II:
Table of Contents

Advertisement

6-13
Appendix - VIBCODE

Measuring VIBCODE Route/ Pool

• Click on 'Route' in the start screen.
• Open the route to be measured.
• Connect the VIBCODE sensor to a VIBCODE measurement
location:
VIBXPERT reads the coding of the measurement location and checks
if this is created in the route. If VIBXPERT finds a measurement task,
measurement starts automatically. If all measurement tasks at the
measurement location are complete, plug the VIBCODE sensor into
the next VIBCODE measurement location and continue measurement
of the route.
If VIBXPERT finds the measurement location in the VIBCODE pool,
the measurement task scheduled first starts automatically. All other
measurements must be triggered manually via the measurement
task selection.
To return to route mode from pool mode, press the MENU button and
click on 'Route'.
If the VIBCODE measurement location is not contained in either the
route or in the pool, change to the 'Multimode' mode to perform the
required measurement. To do so, click on 'Multimode' in the message
window or press the MENU button and click on 'Multimode'. Under
certain circumstances it may be necessary to change the transducer
in the task manager to 'VIBCODE' beforehand. After saving the
measurement result, repeatedly press the ESC button to return to
the route mode.
Unknown VIBCODE location

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vib 5.310

Table of Contents