Delta ASD-A2 Series User Manual page 550

Table of Contents

Advertisement

Chapter 9 Communications
P3-02
PTL
Operational
Interface:
Default: 6
Control
Mode:
Unit: -
Range: 0 ~ 0x8
Data Size: 16-bit
Format: Hexadecimal
Settings: The definition of the setting value is as the followings:
P3-05
CMM
Operational
Interface:
Default: 0
Control
Mode:
Unit: -
Range: 0x00 ~ 0x01
Data Size: 16-bit
Format: Hexadecimal
Settings: Communication port can select one or more than one communications.
Revision February, 2017
Communication Protocol
Panel / Software
ALL
0: 7, N, 2 (MODBUS, ASCII)
1: 7, E, 1 (MODBUS, ASCII)
2: 7, O,1 (MODBUS, ASCII)
3: 8, N, 2 (MODBUS, ASCII)
4: 8, E, 1 (MODBUS, ASCII)
5: 8, O, 1 (MODBUS, ASCII)
6: 8, N, 2 (MODBUS, RTU)
7: 8, E, 1 (MODBUS, RTU)
8: 8, O, 1 (MODBUS, RTU)
Communication Mechanism
Panel / Software
ALL
Communication Interface
0: RS232
1: RS485
Communication
Communication
ASDA-A2
Address: 0304H
0305H
Related Section:
9.2
Address: 030AH
030BH
Related Section:
9.2
9-5