ASDA-A2
P5-08
SWLP Forward Software Limit
Operational
Interface:
Default: 2147483647
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Format: Decimal
Settings: In PR mode, if the motor rotates in forward direction and its command
P5-09
SWLN Reverse Software Limit
Operational
Interface:
Default: -2147483648
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Format: Decimal
Settings: In PR mode, if the motor rotates in reverse direction and its command
Revision February, 2017
When PR is triggered by DI, the reading value is the same
For example:
Set P5-07 to 3, PR#3 will be triggered.
If the reading value is 3, it means PR #3 is incomplete.
If the reading value is 10003, it means PR#3 is issued completed, but
the motor has not reached the target position yet.
If the reading value is 20003, it means PR#3 is issued completed and
the motor has reached the target position.
Panel / Software
PR
Unit: PUU
position exceeds the setting value of P5-08, it will trigger AL.283.
Panel / Software
PR
Unit: PUU
position exceeds the setting value of P5-09, it will trigger AL.285.
Communication
Communication
Chapter 8 Parameters
Address: 0510H
0511H
Related Section: -
Address: 0512H
0513H
Related Section: -
8-165