ASDA-A2
P1-04
MON1 MON1 Analog Monitor Output Proportion
Operational
Interface:
Default: 100
Control
Mode:
Unit: % (full scale)
Range: 0 ~ 100
Data Size: 16-bit
Format: Decimal
Settings: Please refer to parameter P0-03 for the setting of analog output
P1-05
MON2 MON2 Analog Monitor Output Proportion
Operational
Interface:
Default: 100
Control
Mode:
Unit: % (full scale)
Range: 0 ~ 100
Data Size: 16-bit
Format: Decimal
Settings: Please refer to parameter P0-03 for the setting of analog output
Revision February, 2017
Panel / Software
ALL
selection.
For example:
P0-03 = 0x00 (MON1 is the speed analog output)
When the output voltage value of MON1 is V1:
Motor speed = (Max. speed × V1/8) × P1-04/100
Panel / Software
ALL
selection.
For example:
P0-03 = 0x00 (MON2 is the speed analog output)
When the output voltage value of MON2 is V2:
Motor speed = (Max. × V2/8) × P1-05/100
Chapter 6 Control Mode of Operation
Communication
Communication
Address: 0108H
0109H
Related Section:
6.4.4
Address: 0108H
0109H
Related Section:
6.4.4
6-55