ASDA-A2
Setting Value: 0x45
DI Name
INHP
In position mode, when this DI is ON, the external pulse input
command is not working.
(Note: The function has to be set to DI8 so as to ensure the
instantaneity of pulse prohibition)
Setting Value: 0x46
DI Name
STOP
Motor stops
Setting Value: 0x47
DI Name
PFQS
This DI can be used to stop the emergency stop of deceleration
time. The setting of deceleration time is identical to P5-03. When
DI.PFQS is on, AL35F will occur. Then, motor starts to
decelerate. When the speed reaches 0, AL3CF occurs and servo
is off. Please turn on DI.ARST to servo on the drive again.
NOTE
1)11 ~ 17 Single control modes; 18~20 Dual control mode.
2)When P2-10 ~ P2-17 is set to 0, DI has no function.
Revision February, 2017
Function Description of Digital Input (DI)
Function Description of Digital Input (DI)
Function Description of Digital Input (DI)
Chapter 8 Parameters
Trigger
Control
Method
Mode
Level
PT
triggered
Trigger
Control
Method
Mode
Rising
PR
edge
triggered
Trigger
Control
Method
Mode
Rising
edge
PT,PR,T,S
triggered
8-287