Delta ASD-A2 Series User Manual page 345

Table of Contents

Advertisement

Chapter 8 Parameters
P2-06
KVI
Operational
Interface:
Default: 100
Control
Mode:
Range: 0 ~ 1023
Data Size: 16-bit
Format: Decimal
Settings: Increasing the value of speed integral compensation can enhance
P2-07
KVF
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 100
Data Size: 16-bit
Format: Decimal
Settings: When the speed control command runs smoothly, increasing the gain
8-94
Speed Integral Compensation
Panel / Software
ALL
Unit: rad/s
speed response and diminish the deviation of speed control. However,
if the value is set too big, it would easily cause resonance and noise.
Speed Feed Forward Gain
Panel / Software
ALL
Unit: %
value can reduce the speed command error. If the command does not
run smoothly, decreasing the gain value can reduce the mechanical
vibration during operation.
Communication
Communication
ASDA-A2
Address: 020CH
020DH
Related Section:
6.3.6
Address: 020EH
020FH
Related Section:
6.3.6
Revision February, 2017

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents