Natural To Lp Gas Conversion Instructions; Orifice Sizes Requirement; Recommended Procedure To Convert This Fireplace To Burn Lpg - Mendota DXV35 DT4-LX Installation & Operating Instructions Manual

Gas direct vent fireplace with premium texture fiber logs combustion system
Table of Contents

Advertisement

NATURAL TO LP GAS CONVERSION INSTRUCTIONS

Kit # HA-30-00507 Mendota Model DXV35 DT4
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. If the in-
formation in these instructions is not followed exactly, a fire, explosion
or production of carbon monoxide may result causing property dam-
age, personal injury or loss of life. The qualified service agency is re-
sponsible for the proper installation of this kit. The installation is not
proper and complete until the operation of the converted appliance is
checked as specified in the owner instructions supplied with the kit.
Caution: The electrical supply to the fireplace must be turned off prior
to performing the conversion. The gas supply must be shut off prior to
disconnecting the electrical power.

ORIFICE SIZES REQUIREMENT:

A Natural Gas to LPG conversion kit #HA-30-00507 is Optional and
must be purchased separately.
LP Conversion Kit # HA-30-00507 contains the following parts: One Motorized LP Pressure Regulator #907.012, and two
Cap Orifices #65-14-00364(drill #3/64") and an L-shaped Torx wrench.

RECOMMENDED PROCEDURE TO CONVERT THIS FIREPLACE TO BURN LPG

This Fireplace Insert arrives from the factory ready to burn Natural Gas. If you intend to burn LPG, it is highly recommend-
f i r e - p a r t s . c o m
ed that you convert this fireplace and its Pressure Regulator, Pilot Orifice Thimble and Burner Orifices prior to placing this
fireplace in its fireplace cavity.
See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1. Using a ¼" Hex Driver, remove 2 screws that secure the Rear and Front burners to the Burner Airbox.
2. Lift Up and remove Front Burner.
3. Loosen Front Burner Air Shutter Screw and rotate air shutter open ¼" minimum. Set burner aside.
4. Slide Rear Burner to the right about 2" and lift up and remove from Firebox.
REAR BURNER
[10.0-5.5"WC]
#65-14-00054[54 DRILL]
#65-14-00055[55 DRILL]
BURNERS MOUNTING
SCREWS
48
Motorized
LP Pressure
Regulator
# 907.012
Burner Orifices
FRONT BURNER

Advertisement