NATURAL TO LP GAS CONVERSION INSTRUCTIONS

Kit # HA-30-00507 Mendota Model DXV35 DT4
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire, explo-
sion or production of carbon monoxide may result causing property
damage, personal injury or loss of life. The qualified service agency
is responsible for the proper installation of this kit. The installation is
not proper and complete until the operation of the converted appli-
ance is checked as specified in the owner instructions supplied with
the kit.
Caution: The electrical supply to the fireplace must be turned off prior to
performing the conversion. The gas supply must be shut off prior to
disconnecting the electrical power.

ORIFICE SIZES REQUIREMENT:

A Natural Gas to LPG conversion kit #HA-30-00507 is Optional and must
be purchased separately.
LP Conversion Kit # HA-30-00507 contains the following parts: One Motorized LP Pressure Regulator #907.012, and two Cap
Orifices #65-14-00364(drill #3/64") and an L-shaped Torx wrench.

RECOMMENDED PROCEDURE TO CONVERT THIS FIREPLACE TO BURN LPG

This Fireplace Insert arrives from the factory ready to burn Natural Gas. If you intend to burn LPG, it is highly recom-
mended that you convert this fireplace and its Pressure Regulator, Pilot Orifice Thimble and Burner Orifices prior to plac-
ing this fireplace in its fireplace cavity.
See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1. Using a ¼" Hex Driver, remove 2 screws that secure the Rear and Front burners to the Burner Airbox.
2. Lift Up and remove Front Burner.
3. Loosen Front Burner Air Shutter Screw and rotate air shutter open ¼" minimum. Set burner aside.
4. Slide Rear Burner to the right about 2" and lift up and remove from Firebox.
REAR BURNER
[10.0-5.5"WC]
#65-14-00054[54 DRILL]
#65-14-00055[55 DRILL]
BURNERS M O UNTING
SC REW S
49
Motorized
LP Pressure
Regulator
# 907.012
Burner Orifices
FRO NT BURNER