L.p. Gas Minimum Height Horizontal Termination - Mendota DXV35 DT4-LX Installation & Operating Instructions Manual

Gas direct vent fireplace with premium texture fiber logs combustion system
Table of Contents

Advertisement

L.P. G
f i r e - p a r t s . c o m
For L.P. gas and high altitude installations (above 4,000 ft.), 45° elbows must be used in place of 90° elbows.
NOTE: This requires 22" minimum height to center of vent cap.
CAUTION: If 90° elbows must be used, a 24 inch vertical starter section must be used off the top of the fireplace.

L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION

H
A
AS OR
IGH
LTITUDE
WALL THIMBLE
REQUIRED
6" COAX
45° COAX
45° COAX VENT
12" COAX
(
4,000
. BUT BELOW 7500 FT.)
ABOVE
FT
(MIN.)
(MIN.)
85-03-00531
15 1/2"
Figure 7: LP MINIMUM VENT
19
TERMINATION CAP
22"
(MIN.)
49 1/4"
(MIN.)